Q. |
Is Cyber Aqualand a dive computer? |
|
A. |
Yes, it is. It calculates the non-decompression limit time from the
diving depth and time according to the decompression theory of DCIEM. |
|
Q. |
What is the difference between Cyber Aqualand and Hyper Aqualand? |
|
A. |
=> |
Cyber Aqualand calculates the residual Nitrogen in body from the
diving depth, diving time and record of the previous diving, and displays
reference information of various types for safe diving (Dive computer function). |
=> |
Cyber Aqualand distinguishes the Skin diving and Scuba diving and
records them in separate logs. It detects automatically according to the
diving condition. |
=> |
Cyber Aqualand can transfer the diving log and profile data into
a personal computer through the communication unit (USB connection) which
should be included in a package or through infrared communication function. |
=> |
Cyber Aqualand can set various functions of the watch through a personal
computer.
/Add and edit Travel Locations
/Setting of Alarm, Destination timer, etc.
/Setting of Dive Alarm and presetting Dive No.
/Setting of Daily graphic and Anniversaries |
=> |
Cyber Aqualand can use infrared communication function in order to
set the time, Alarm, and Dive Alarm of another watches. |
=> |
Cyber Aqualand does not need to replace the battery since it has
a charging function, |
|
Q. |
What are the specifications and features of Cyber Aqualand? |
|
A. |
<Watch Body>
Movement No. |
D700 (meeter) / D706 (feet) |
Operating temperature range |
0`+50
0 degree C to +50 degree C (32 degree F to 122 degree F) |
Accuracy |
+/-20 seconds per month on average (when worn at a normal temperature of
+5 degree C to +35 degree C (41degree F to 95 degree F)) |
Water depth gauge accuracy |
Within +/-(3% of displayed value + 0.3 m (1ft)) (when using at a constant
temperature)
Guaranteed accuracy temperature range: +10 degree C to +40 degree C (50
degree F to 104 degree F) (accuracy of water depth measurement is subjected
to the effects of changes in the temperature at which the watch is worn) |
Depth measurement range
|
1m to 80m |
Water temperature measurement accuracy |
Displayed value +/-3 degree C (6 degree F) |
Modes and Main Functions |
Time |
Hours, minutes, seconds, location, Battery charge indicator, daily
graphic (must be set with PC) |
Date |
Month, date, day, year (during correction only) |
Travel Time |
Month, date, hours, minutes, seconds, location, time difference from UTC
and time of time mode |
Destination Timer |
Time remaining until arrival at destination, arrival time (location, month,
date, day, hours, minutes) |
Alarm |
Alarm time (hours, minutes) |
Chronograph |
Hours, minutes, seconds, 1/100 seconds, split time (time measured for 100
hours) |
Timer |
Minutes, seconds (can be set up to 99 minutes in 1 minute units) |
System Monitor |
Battery charge indicator, flash memory status display |
Dive Plan |
Dive number, body nitrogen level graph, no-decompression limit time, depth
alarm (setting of depth and number of times alarm sounds), dive time alarm
(setting of dive time) |
Scuba Diving Log |
Total number of dives, dive date, dive number, S.I. time, time in, dive
time, min. water temperature, record of decompression diving, max. depth,
average depth, profile log |
Skin Diving Log |
Dive date, dive number, max. depth, time in, dive time, deepest depth ever
recorded and date recorded |
Dive |
Current time, current depth, dive time, max. depth, no-decompression limit
time, water temperature, body nitrogen level graph, safety stop graph,
safety stop time, decompression stop indicator, decompression stop graph |
Surface mode |
Elapsed time after diving (max. 24 hours), no fly time |
Infrared communication mode |
(Complies with the international standard Irww(IrDA for Wrist Watches)).
|
Low power mode |
Time display, date display, no display |
Other Additional Functions |
/EL light
/Water sensor
/Various warning functions (insufficient charge warning, file error warning,
abnormal pressure detection error warning, water sensor check warning,
ascent rate warning, abnormal depth warning, decompression diving warning,
limit depth warning, permanent error warning)
/Data communication functions: Data communication using infrared and USB
interfaces (for data transfer between watch and a personal computer or
between two watches)
* Data communication operating temperature range: +10 degree C to +35 degree
C (50 degree F to 95 degree F) |
Battery |
Secondary battery, 1 pc. (charged by communication unit) |
Continuous Usage Times: |
/From fully charged to insufficient charge warning: Approx. 1 month
/From insufficient charge warning to low power mode: Approx. 2 days
/From low power mode to watch stopping: Approx. 3 days
* Refer to the section on " Battery charge Indicator and Continuous
Usage Time" for information on the operating conditions for continuous
usage times. |
<Communication Unit>
Model |
CMUT-02 (used exclusively with watch movement no. D700 / D706) |
Applications |
Charging and data communication using USB cable |
Operating and storage conditions |
Temperature +10 degree C to +40 degree C (50 degree F to 104 degree F),
humidity 20% to 80% (no condensation of moisture) |
Power Source |
/During data communication: Uses power supplied by USB cable
/During charging: 4 size AA alkaline batteries
|
Current Consumption |
/During data communication: Max. 30 mA
/During charging: 20 mA |
Dimensions |
Dimensions: 10.2(W) x 9.1(D) x 6.9(H) cm (4.0(W) x 3.6(D) x 2.7(H) inch) |
Weight |
125 g (excluding batteries) |
* Specifications are subject to change without notice. |
|
Q. |
What are the size and weight of Cyber Aqualand? |
|
A. |
The sizes of watch body are the following.
/Width:47.4mm(1.9inch)
/Height:51.2mm(2.0inch)
/Thickness:16mm(0.6inch)
The weight with Stainless Steel body with rubber strap is 130g.
The weight with Stainless Steel body with metal bracelet is 220g. |
|
Q. |
What is the memory capacity of the watch ? |
|
A. |
A maximum of 100 sets of log data can be recorded for both Scuba
diving and Skin diving. Anniversaries can be set up to 366 days, however,
memory area is not distinguished either one so that if Anniversaries are
set fully, the maximum sets of log data can be reduced. |
|
Q. |
Is Cyber Aqualand applicable to Nitrox diving ? |
|
A. |
No, it isn't. It is applicable to only air diving. |
|
Q. |
Is Cyber Aqualand applicable to high-altitude diving ? |
|
A. |
No, it isn't. It is not applicable to high-altitude diving and fresh
water diving. |
|
Q. |
Which OS's are applicable ? |
|
A. |
Applicable OS are Windows 98, Windows 98SE, Windows Me, Windows 2000,
and Windows XP, however the Mac OS is not applicable.
|
|
Q. |
What is the minimum requirement of PC for installation of Aqualand Graph
? |
|
A. |
<PC>
/CPU: Pentium 200MHz or higher
/OS: Windows 98, Windows 98SE, Windows Me, Windows 2000,Windows XP
/Minimum available memory if 32MB(64MB or more is recommended)
/100MB or more(recommended) usable area of hard disk.
/Display having resolution of SVGA(800 x 600, 256 colors) or higher
<Other items>
/USB or IrDA port
/CD-ROM drive is necessary for installation |